Show simple item record

dc.contributor.authorLeuschen, Martin L.
Cavallaro, Joseph R.
Walker, Ian D.
dc.date.accessioned 2012-05-18T19:04:47Z
dc.date.available 2012-05-18T19:04:47Z
dc.date.issued 2001-03-01
dc.identifier.otherhttp://scholar.google.com/scholar?cluster=15504886398306691804&hl=en&as_sdt=0,44
dc.identifier.urihttps://hdl.handle.net/1911/64162
dc.description.abstract One of the most important areas in the robotics industry is the development of robots capable of working in hazardous environments. Providing a high level of functionality in these arenas is important simply because humans cannot safely or cheaply work there. Our work focuses on a fault detection method known as analytical redundancy, or AR. AR is a model-based state-space technique that is theoretically guaranteed to derive the maximum number of independent tests of the consistency of sensor data with the system model and past control inputs. AR is only valid for linear sampled data systems. AR is a model-based technique, and is thus extremely sensitive to differences between the nominal model behavior and the actual system behavior. A system with strong nonlinear characteristics, such as a hydraulic servovalve, can be impossible to model properly in the linear domain, creating significant differences between the model and the system that will generate false error signals. In this paper we discuss the application to a hydraulic servovalve system of our novel rigorous nonlinear AR technique that maintains traditional linear AR's theoretical guarantee of the maximum possible number of independent tests in the nonlinear domain. This technique allows us to gain the benefits of AR testing for nonlinear systems with both continuous and sampled data.
dc.description.sponsorship National Science Foundation
dc.description.sponsorship Sandia National Laboratory
dc.language.iso eng
dc.publisher American Nuclear Society
dc.subjectRobotics
Hydraulic servovalve
Nonlinear systems
dc.title Testing on the Curve: Nonlinear Analytical Redundancy for Fault Detection
dc.type Conference paper
dc.contributor.org Center for Multimedia Communication
dc.citation.pageNumber Session 22, Paper F131
dc.citation.location Seattle, WA
dc.citation.conferenceName Ninth ANS Topical Meeting on Robotics and Remote Systems
dc.citation.conferenceDate 2001
dc.type.dcmi Text
dc.type.dcmi Text
dc.identifier.citation M. L. Leuschen, J. R. Cavallaro and I. D. Walker, "Testing on the Curve: Nonlinear Analytical Redundancy for Fault Detection," pp. Session 22, Paper F131, 2001.